Conduit Installation

Method Statement For Installation Of Galvanized Conduits On Exposed Surface

Method Statement For Installation Of Galvanized Conduits On Exposed Surface

Method Statement For Installation Of Galvanized Conduits that has to be installed on the Exposed Surface of a building is described here. This method of statement specify the detailed requirements and procedures for the installation of Galvanized Conduits for the exposed surface installation requirement for MEP services of the above building.

Construction Specification For Electrical Busbar Trunking (Bus Duct) System

Busbar Trunking System
Busbar Trunking System (BBT) in electrical construction, uses to transporting electrical power to a shorter distance but many utilization point, say, within the building or a compound of facilities. Though cables can also be used in these areas, their economic impact would be high if compared to the effective Busbar Trunking System. It will help us to tap power directly from where we want it to be and make utilize to the service point.

Typical Mounting Details Of Fire Alarm Detectors

Typical Mounting Detail Of Fire Alarm Detectors mounted on false ceiling
These typical drawings show how to install smoke detectors and heat detectors used in Fire Alarm system on false ceiling. The installation shall be as per the relevant section in the contract specification and drawing has the following major points: Smoke detector mounted on false ceiling with the help of loop in box; Firetuff or equivalent cable run under the RCC slab clipped to the soffit; Cable size shall be 2 core 1.5 sq. mm copper; Cable has to be looped to the detector and tied as shown in the drawing.

Typical Mounting Details Of Fire Alarm Break Glass Manual Call Point

Typical Mounting Detail Of Fire Alarm Break Glass Manual Call Point

These drawings show how to install Fire Alarm Break Glass (BG) or Manual Call Point (MCP) on walls. It has to be mounted on back box installed in the wall. This box (embedded or exposed as specified in the concerned section of the specification) has to be connected through GI / PVC conduit that will have the Firetuff or equivalent cable to be looped for other detectors.

Conduit Wiring In Electrical Construction Contract Works

Electrical Power Layout Conduit Installation

Scope of Work of this this sample specification covers the supply, installation, testing and commissioning of all wiring materials for power and lighting in concealed and/or surface conduits.

1. Applicable Standards

The conduits shall conform to IS 9537 I & II  or equivalent standards. Switches, Plug Sockets shall conform to IS 3854 and IS 4615, however, contractor shall comply with the latest or superseded versions of IS/BIS to be used for the complete work.